LPCB Approved Fire Suppression System
It is an automatic fire suppression system & is mainly designed to attack fire at the first stage/ Initial stage itself. It is simple, cost effective & maintenance free. As we know, most of the fire accidents are caused by short circuits which is usually start from electrical panel boards & other concealed places which are unmanned at night.
The system comprises of a cylinder charged with the extinguishing agent (cylinder), actuation value, pressure gauge, polymer heat & flame detection tube, spring top, end adapter, Nipple & ball value etc.,
POWDER TYPE FIRE EXTINGUISHER (MAP 90%) Technical Specification:-
Capacity | 1 Kg | 2 Kg | 4 Kg | 6 Kg | 9 Kg |
---|---|---|---|---|---|
MAP Content | 90% | 90% | 90% | 90% | 90% |
Fire Rating | 1A 21B | 1A 34B | 3A 89B | 4A 144B | 6A 233B |
Diameter (MM) | 85±0.5 | 107±0.5 | 140±0.5 | 160±0.5 | 174±0.5 |
Total Height (MM) | 328±2 | 380±2 | 432±2 | 475±2 | 575±2 |
Empty weight (KG) Approx. | 1.1 | 1.3 | 2 | 2.4 | 3.1 |
Full weight (KG) Approx | 2.1 | 3.3 | 6 | 8.4 | 12.1 |
Avg. Effective Discharge Time | 08 SEC | 10 SEC | 14 SEC. | 20 SEC. | 23 SEC. |
Operating temperature | -20°C TO +60°C | -20°C TO +60°C | -20°C TO +60°C | -20°C TO +60°C | -20°C TO +60°C |
Service Pressure | 15 bar | 15 bar | 15 bar | 15 bar | 15 bar |
Maximum Service Pressure | 16.5 bar | 16.5 bar | 16.5 bar | 16.5 bar | 16.5 bar |
Test Pressure | 35 bar | 35 bar | 35 bar | 35 bar | 35 bar |
SUPPRESSION AGENT - FK5112 CLEAN AGENT GAS
- Chemical – Dodecfluoro -2- methylpentan -3-one
- Zero ozone depletion potential
- 5-day atmospheric lifetime
- Low Global warming potential
- Electrically non conductive
- UL Recognized and FM Approved
Method of Recommendation
- The fire suppression system is recommended as per the LPCB requirement, ensuring the Quality and Reliability, which has gone the Stringent Tests at UK Lab Viz.
- Apart from the UK Lab tests the manufacturing facility in India has gone through the manufacturing and documentation Audit along with the installation audit successfully at various client sites.
- The system alerts the incident through the Indication panel and been tested with the following tests.
Fire Suppression System Benefits
- Automatic Fire Detection & Suppression System
- Initial Level of Fire Fighting
- No Man Power, No Power Supply
- Zero Ozone Depletion Potential
- Chemical - Dodecfluoro-2-Methylpentan-3-One (FK-5-1-1-2)
- 5-day Atmospheric Lifetime
- Low Global Warming Potential Electrically Non-Conductive UL Recognized and FM Approved Low Global Warming Potential
- Electrically Non-Conductive
- UL Recognized and FM Approved
Tests Undergone
- Fire Extinguishment Test
- System Discharge Test
- Component Examination and Test
- Pneumatic Heat Detector Agent Test
- Post Aging Test
Characteristics of Agent are
- Zero ozone depletion potential
- Low global warming potential
- Five-day atmospheric lifetime
- Safe for people and animal
- Electrical nonconductive
Approvals
- The System is with LPCB Approval and the Certificate Number is LPS: 1666: Issue 1.0Cert/LPCB ref. 1604a
- The product is also CE approved & the certificate no is 23407.
- Approval For Extinguishing Agent
- UL Approval & FM approval.